Cerberus PRO Interactive - FC722-ZA
PRODUCTS

Cerberus PRO Interactive – FC722-ZA

PROJECT
OFFER
GET !

    GET A PROJECT OFFER

    You can fill out our form to get a project proposal.

    Why are Fire Warning Systems Important?

    While fire is one of the most important risks threatening human life and property, the most successful solution against these risks is fire alarm systems. Fire detection systems should be used in order to minimize the loss of life and property and to minimize the effects of fire. So, why should these systems be used? What kind of advantages does the fire detection system provide?

    Why are Fire Warning Systems Important?

    It is not possible to foresee and prevent the fire, which can be considered as a situation that will seriously endanger human life. However, it is possible to intervene quickly by determining the time of the fire. Fire warning and alarm systems also provide a solution in this regard. With the help of sensors placed in areas where fire is likely to occur, detection systems are enabled to work.

    Smoke or fire detected by the sensors is reported to the center, providing a quick response opportunity. It will be possible to achieve successful results with fire extinguishing solutions that will work integrated with fire detection and notification systems. With fire detection systems that make human life easier and bring safety to the fore, you can produce solutions in different areas, especially in the home and workplace.

    Read More
    Cerberus PRO Interactive – FC722-ZA
    FC722-ZA
    Product Features

    The FC722-ZA (2-loop, expandable to 4) is a compact fire control panel with an integrated operating unit that can process signals from Cerberus™ PRO devices up to 252 addresses.

    The fire control panel can be used as a standalone version or networked.

    It can be programmed with a user-friendly Cerberus-Engineering-Tool to create a versatile system.

    Up to 32 fire control panels and fire terminals can be connected to a single cluster (C-WEB/SAFEDLINK network), or up to 16 panels when the cluster is connected to a hazard management system.

    Using a fiber optic backbone (C-WEB/LAN), up to 14 of these clusters can be networked with up to 16 panels each.

    This topology enables the creation of an EN 54 compliant network with up to 64 fire control panels and fire terminals.

    All detector lines are monitored for earth faults.

    Customization of user text directly in the terminal or with the Cerberus-Engineering-Tool Up to 2000 events can be stored according to various criteria.

    Automatic summer/winter time change.

    Detection and auto-reading (auto-configuration) of all C-NET devices provides instant simple operation.

    Stored data can be loaded via Cerberus-Remote access.

    The FC722-ZA is ideal for medium-sized applications, eg. workshops, hotels, etc. or when networked as part of much larger applications, the FC722-ZA with flexible cross-linking possibilities can also be used for extensive systems.

    Expansion and accessories must be ordered separately.

    Technicial Specifications
    • Detector compatibility Cerberus PRO FD720
    • Number of addresses 252
    • Number of detector lines 2 (4) loops or 4 (8) stub lines
    • Programmable input/output 8
    • Relay outputs 1x RT alarm , 1x RT fault
    • Supervised output 1x RT alarm , 1x RT fault , 1x Horn
    • Mains voltage AC 230 V
    • Operating voltage DC 21…28.4 V
    • Operating current 5000 mA
    • Power supply 150 W
    • Bypass time for emergency power supply 72 h
    • Battery capacity 2 x 12 V, 26 Ah
    • Plug-in position 2 -> for serial interfaces RS232, RS485 , 2 -> for network modules , 1 -> for loop extension (C-NET)
    • Operating temperature '-8…42 °C
    • Storage temperature '-20…+60 °C
    • Relative humidity ≤95 % rel. (no condensation)
    • Protection category IP30
    • Color housing/cover Light grey, ~RAL 7035 / Gray, ~RAL 050 00 00
    • Cabinet dimensions (W x H x D) 430 x 796 x 160 mm (without cover cap) 430 x 796 x 188 mm (with cover cap)
    • Accessories DL3750+ Matrix printer (Extern) , FCA1209-Z1 Output module (230 V) , FCA2014-A1 Cable kit (communication) , FHA2015-A1 Flush mounting bezel two HU , FHA2016-A1 19" mounting kit , FHA2017-A1 Flush mounting bezel one HU , FTO2005-C1 Key switch (Kaba) , FTO2006-B1 Key switch (Nordic) , Z3B171 Relay module
    • Expansion FCA2001-A1 RS232 module (isolated) , FCA2002-A1 RS485 module (isolated) , FCA2005-A1 Sounder module , FCA2031-A1 Connection module (MoNet) , FCA2033-A1 License key (S1) , FCA2034-A1 License key (S2) , FCA2035-A1 License key (S3) , FCI2001-A1 Fire brigade periphery module , FCI2003-A1 Loop extension (FDnet/C-NET) , FH7202-Z3 Housing (Standard) , FH7203-Z3 Housing (Comfort) , FHA2007-A1 Mounting plate , FHA2035-A1 Mounting kit (marine) , FN2001-A1 Network module (SAFEDLINK) , FN2006-A1 Fiber network module (SM) , FN2007-A1 Fiber network module (MM) , FN2012-A1 Ethernet Switch (modular) , FP2005-A1 Power supply kit (150 W, B) , FTO2001-A1 Event printer , NK8237.2 Modbus Gateway , VN2001-A1 Ethernet Module (electric/CAT5) , VN2002-A1 Ethernet Module (MM) , VN2003-A1 Ethernet Module (SM)